Push-in Fittings
Choose the connection shape, then match tube outside diameter and port thread. Compare straight, elbow and branch fittings alongside flow-control components.

Find the right connection.
Compare the form and tube interface first. Open a series to review its parameters and prepare the required configuration.
20 series

DHVFF Series
Manual hand valve
- Tube / port options
- Tube 4–12 mm / various
Sizes & ordering

DHVFF Series
Manual hand valve.
- Connection form
- Manual hand valve
- Ordering prefix
- HVFF
- DHVFF is the series display name. Order codes use HVFF; retain the listed code when specifying the fitting.
- Specify the required control function and flow direction together with tube size. Confirm the selected valve circuit and operating conditions.
| Series | Tube / port options | Connection form |
|---|---|---|
| DHVFF Series | Tube 4–12 mm / various | Manual shut-off valve |
Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.
| Listed code |
|---|
| HVFF-4 |
| HVFF-6 |
| HVFF-8 |
| HVFF-10 |
| HVFF-12 |
Prepare this configuration
Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.
Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.
Copy your model and options into the requirement brief.

DLSA Series
In-line flow controller
- Tube / port options
- Tube-to-tube; listed LSA sizes 4, 6, 8, 10, 12
Sizes & ordering

DLSA Series
In-line flow controller.
- Connection form
- In-line flow controller
- Ordering prefix
- LSA
- DLSA is the series display name. Order codes use LSA; retain the listed code when specifying the fitting.
- Specify the required control function and flow direction together with tube size. Confirm the selected valve circuit and operating conditions.
| Series | Tube / port options | Connection form |
|---|---|---|
| DLSA Series | Tube-to-tube; listed LSA sizes 4, 6, 8, 10, 12 | In-line flow control |
Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.
| Listed code |
|---|
| LSA-4 |
| LSA-6 |
| LSA-8 |
| LSA-10 |
| LSA-12 |
Prepare this configuration
Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.
Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.
Copy your model and options into the requirement brief.

DPG Series
Straight reducing union
- Tube / port options
- Unequal tube pairs; select the complete PG code
Sizes & ordering

DPG Series
Straight reducing union.
- Connection form
- Straight reducing union
- Ordering prefix
- PG
- DPG is the series display name. Order codes use PG; retain the listed code when specifying the fitting.
| Series | Tube / port options | Connection form |
|---|---|---|
| DPG Series | Unequal tube pairs; select the complete PG code | Straight reducing union |
Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.
| Listed code |
|---|
| PG6-4 |
| PG8-4 |
| PG10-8 |
| PG12-10 |
| PG10-6 |
| PG12-8 |
| PG16-12 |
Prepare this configuration
Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.
Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.
Copy your model and options into the requirement brief.

DPK Series
Five-port union
- Tube / port options
- Five tube ports; listed PK sizes 4, 6, 8, 10, 12
Sizes & ordering

DPK Series
Five-port union.
- Connection form
- Five-port union
- Ordering prefix
- PK
- DPK is the series display name. Order codes use PK; retain the listed code when specifying the fitting.
| Series | Tube / port options | Connection form |
|---|---|---|
| DPK Series | Five tube ports; listed PK sizes 4, 6, 8, 10, 12 | Five-port union |
Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.
| Listed code |
|---|
| PK-4 |
| PK-6 |
| PK-8 |
| PK-10 |
| PK-12 |
Prepare this configuration
Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.
Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.
Copy your model and options into the requirement brief.

DPM Series
Bulkhead straight union
- Tube / port options
- Tube-to-tube bulkhead; listed PM sizes 4, 6, 8, 10, 12
Sizes & ordering

DPM Series
Bulkhead straight union.
- Connection form
- Bulkhead straight union
- Ordering prefix
- PM
- DPM is the series display name. Order codes use PM; retain the listed code when specifying the fitting.
| Series | Tube / port options | Connection form |
|---|---|---|
| DPM Series | Tube-to-tube bulkhead; listed PM sizes 4, 6, 8, 10, 12 | Bulkhead straight union |
Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.
| Listed code |
|---|
| PM-4 |
| PM-6 |
| PM-8 |
| PM-10 |
| PM-12 |
Prepare this configuration
Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.
Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.
Copy your model and options into the requirement brief.

PB Series
Male branch tee
- Tube / port options
- Tube 4–12 mm; male thread M5–1/2"
Sizes & ordering

PB Series
Male branch tee.
- Connection form
- Male branch tee
- Ordering prefix
- PB
| Series | Tube / port options | Connection form |
|---|---|---|
| PB Series | Tube 4–12 mm; male thread M5–1/2" | Branch tee with male thread |
Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.
| Order-code group |
|---|
| PB4-M5/M6 |
| PB4-01/02/03/04 |
| PB6-M5/M6 |
| PB6-01/02/03/04 |
| PB8-01/02/03/04 |
| PB10-01/02/03/04 |
| PB12-01/02/03/04 |
| PB14-02/03/04/06 |
| PB16-02/03/04/06 |
Prepare this configuration
Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.
Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.
Copy your model and options into the requirement brief.

PC Series
Male straight connector
- Tube / port options
- Tube 4–16 mm; male thread M5–1/2"
Sizes & ordering

PC Series
Male straight connector.
- Connection form
- Male straight connector
- Ordering prefix
- PC
| Series | Tube / port options | Connection form |
|---|---|---|
| PC Series | Tube 4–16 mm; male thread M5–1/2" | Straight push-in connector |
Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.
| Order-code group |
|---|
| PC4-M5/M6 |
| PC4-01/02/03/04 |
| PC6-M5/M6 |
| PC6-01/02/03/04 |
| PC8-01/02/03/04 |
| PC10-01/02/03/04 |
| PC12-01/02/03/04 |
| PC14-02/03/04/06 |
| PC16-02/03/04/06 |
Prepare this configuration
Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.
Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.
Copy your model and options into the requirement brief.

PCF Series
Female straight connector
- Tube / port options
- Tube 4–12 mm; female thread 1/8–1/2"
Sizes & ordering

PCF Series
Female straight connector.
- Connection form
- Female straight connector
- Ordering prefix
- PCF
| Series | Tube / port options | Connection form |
|---|---|---|
| PCF Series | Tube 4–12 mm; female thread 1/8–1/2" | Straight with internal thread |
Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.
| Order-code group |
|---|
| PCF4-M5/M6 |
| PCF4-01/02/03/04 |
| PCF6-M5/M6 |
| PCF6-01/02/03/04 |
| PCF8-01/02/03/04 |
| PCF10-01/02/03/04 |
| PCF14-02/03/04 |
| PCF16-02/03/04 |
Prepare this configuration
Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.
Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.
Copy your model and options into the requirement brief.

PD Series
Male run tee
- Tube / port options
- Tube 4–12 mm; male thread M5–1/2"
Sizes & ordering

PD Series
Male run tee.
- Connection form
- Male run tee
- Ordering prefix
- PD
| Series | Tube / port options | Connection form |
|---|---|---|
| PD Series | Tube 4–12 mm; male thread M5–1/2" | In-line tee with male thread |
Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.
| Order-code group |
|---|
| PD4-M5/M6 |
| PD4-01/02/03/04 |
| PD6-M5/M6 |
| PD6-01/02/03/04 |
| PD8-01/02/03/04 |
| PD10-01/02/03/04 |
| PD12-01/02/03/04 |
| PD14-02/03/04/06 |
| PD16-02/03/04/06 |
Prepare this configuration
Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.
Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.
Copy your model and options into the requirement brief.

PE Series
Union tee
- Tube / port options
- Tube 4–16 mm (all ports)
Sizes & ordering

PE Series
Union tee.
- Connection form
- Union tee
- Ordering prefix
- PE
| Series | Tube / port options | Connection form |
|---|---|---|
| PE Series | Tube 4–16 mm (all ports) | Equal union tee |
Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.
| Listed code |
|---|
| PE-4 |
| PE-6 |
| PE-8 |
| PE-10 |
| PE-12 |
| PE-14 |
| PE-16 |
Prepare this configuration
Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.
Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.
Copy your model and options into the requirement brief.

PH Series
Male banjo elbow
- Tube / port options
- Tube 4–10 mm; male thread M5–1/2"
Sizes & ordering

PH Series
Male banjo elbow.
- Connection form
- Male banjo elbow
- Ordering prefix
- PH
| Series | Tube / port options | Connection form |
|---|---|---|
| PH Series | Tube 4–10 mm; male thread M5–1/2" | Banjo-type swivel elbow |
Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.
| Order-code group |
|---|
| PH4-M5/M6 |
| PH4-01/02 |
| PH6-M5/M6 |
| PH6-01/02/03/04 |
| PH8-01/02/03/04 |
| PH10-01/02/03/04 |
| PH12-01/02/03/04 |
Prepare this configuration
Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.
Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.
Copy your model and options into the requirement brief.

PL Series
Male elbow
- Tube / port options
- Tube 4–16 mm; male thread M5–1/2"
Sizes & ordering

PL Series
Male elbow.
- Connection form
- Male elbow
- Ordering prefix
- PL
| Series | Tube / port options | Connection form |
|---|---|---|
| PL Series | Tube 4–16 mm; male thread M5–1/2" | 90° male elbow |
Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.
| Order-code group |
|---|
| PL4-M5/M6 |
| PL4-01/02/03/04 |
| PL6-M5/M6 |
| PL6-01/02/03/04 |
| PL8-01/02/03/04 |
| PL10-01/02/03/04 |
| PL12-01/02/03/04 |
| PL14-02/03/04/06 |
| PL16-02/03/04/06 |
Prepare this configuration
Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.
Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.
Copy your model and options into the requirement brief.

PLF Series
Female elbow
- Tube / port options
- Tube 4–12 mm; female thread 1/8–1/2"
Sizes & ordering

PLF Series
Female elbow.
- Connection form
- Female elbow
- Ordering prefix
- PLF
| Series | Tube / port options | Connection form |
|---|---|---|
| PLF Series | Tube 4–12 mm; female thread 1/8–1/2" | 90° female elbow |
Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.
| Order-code group |
|---|
| PLF4-M5/M6 |
| PLF4-01/02/03/04 |
| PLF6-M5/M6 |
| PLF6-01/02/03/04 |
| PLF8-01/02/03/04 |
| PLF10-01/02/03/04 |
| PLF12-01/02/03/04 |
| PLF14-02/03/04 |
| PLF16-01/02/03/04 |
Prepare this configuration
Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.
Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.
Copy your model and options into the requirement brief.

PLL Series
Extended male elbow
- Tube / port options
- Tube 4–12 mm; male thread M5–1/2"
Sizes & ordering

PLL Series
Extended male elbow.
- Connection form
- Extended male elbow
- Ordering prefix
- PLL
| Series | Tube / port options | Connection form |
|---|---|---|
| PLL Series | Tube 4–12 mm; male thread M5–1/2" | Extended 90° elbow |
Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.
| Order-code group |
|---|
| PLL4-M5/M6 |
| PLL4-01/02/03/04 |
| PLL6-M5/M6 |
| PLL6-01/02/03/04 |
| PLL8-01/02/03/04 |
| PLL10-01/02/03/04 |
| PLL12-01/02/03/04 |
Prepare this configuration
Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.
Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.
Copy your model and options into the requirement brief.

PU Series
Union straight connector
- Tube / port options
- Tube 4–16 mm both sides
Sizes & ordering

PU Series
Union straight connector.
- Connection form
- Union straight connector
- Ordering prefix
- PU
| Series | Tube / port options | Connection form |
|---|---|---|
| PU Series | Tube 4–16 mm both sides | Equal union straight |
Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.
| Listed code |
|---|
| PU-4 |
| PU-6 |
| PU-8 |
| PU-10 |
| PU-12 |
| PU-14 |
| PU-16 |
Prepare this configuration
Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.
Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.
Copy your model and options into the requirement brief.

PV Series
Union elbow
- Tube / port options
- Tube 4–16 mm both ports
Sizes & ordering

PV Series
Union elbow.
- Connection form
- Union elbow
- Ordering prefix
- PV
| Series | Tube / port options | Connection form |
|---|---|---|
| PV Series | Tube 4–16 mm both ports | Equal union elbow |
Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.
| Listed code |
|---|
| PV-4 |
| PV-6 |
| PV-8 |
| PV-10 |
| PV-12 |
| PV-14 |
| PV-16 |
Prepare this configuration
Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.
Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.
Copy your model and options into the requirement brief.

PX Series
Male Y connector
- Tube / port options
- Tube 4–12 mm; male thread M5–1/2"
Sizes & ordering

PX Series
Male Y connector.
- Connection form
- Male Y connector
- Ordering prefix
- PX
| Series | Tube / port options | Connection form |
|---|---|---|
| PX Series | Tube 4–12 mm; male thread M5–1/2" | Y-type with male thread |
Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.
| Order-code group |
|---|
| PX4-M5/M6 |
| PX4-01/02/03/04 |
| PX6-M5/M6 |
| PX6-01/02/03/04 |
| PX8-01/02/03/04 |
| PX10-01/02/03/04 |
| PX12-01/02/03/04 |
| PX14-02/03/04/06 |
| PX16-02/03/04/06 |
Prepare this configuration
Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.
Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.
Copy your model and options into the requirement brief.

PY Series
Union Y connector
- Tube / port options
- Tube 4–12 mm all ports
Sizes & ordering

PY Series
Union Y connector.
- Connection form
- Union Y connector
- Ordering prefix
- PY
| Series | Tube / port options | Connection form |
|---|---|---|
| PY Series | Tube 4–12 mm all ports | Equal union Y |
Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.
| Listed code |
|---|
| PY-4 |
| PY-6 |
| PY-8 |
| PY-10 |
| PY-12 |
| PY-14 |
| PY-16 |
Prepare this configuration
Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.
Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.
Copy your model and options into the requirement brief.

PZA Series
Union cross
- Tube / port options
- Tube 4–12 mm all directions
Sizes & ordering

PZA Series
Union cross.
- Connection form
- Union cross
- Ordering prefix
- PZA
| Series | Tube / port options | Connection form |
|---|---|---|
| PZA Series | Tube 4–12 mm all directions | Equal cross union |
Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.
| Listed code |
|---|
| PZA-4 |
| PZA-6 |
| PZA-8 |
| PZA-10 |
| PZA-12 |
Prepare this configuration
Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.
Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.
Copy your model and options into the requirement brief.

SL Series
Speed controller
- Tube / port options
- Tube 4–12 mm; thread M5–1/2"
Sizes & ordering

SL Series
Speed controller.
- Connection form
- Speed controller
- Ordering prefix
- SL
- Specify the required control function and flow direction together with tube size. Confirm the selected valve circuit and operating conditions.
| Series | Tube / port options | Connection form |
|---|---|---|
| SL Series | Tube 4–12 mm; thread M5–1/2" | Meter-out / meter-in type |
Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.
| Order-code group |
|---|
| SL4-M5/M6 |
| SL4-01/02 |
| SL6-M5/M6 |
| SL6-01/02/03/04 |
| SL8-01/02/03/04 |
| SL10-01/02/03/04 |
| SL12-01/02/03/04 |
Prepare this configuration
Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.
Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.
Copy your model and options into the requirement brief.
No matching series. Try a model prefix or connection shape.
Compare the routing options.
One-touch fittings connect calibrated PU or PA tubing to pneumatic ports and to other tubes. Choose straight and elbow connectors, branches, panel feedthroughs or flow-control components, then match the tube outside diameter, port thread and connection function independently.
| Series | Connection / function | Circuit use |
|---|---|---|
| DHVFF Series | Manual hand valve | Line isolation, maintenance point, local on/off control |
| DLSA Series | In-line flow controller | Cylinder speed control, small pneumatic actuators |
| DPG Series | Straight reducing union | Join two different tube outside diameters in a straight line. |
| DPK Series | Five-port union | Connect five tube lines at one distribution junction. |
| DPM Series | Bulkhead straight union | Join two tube lines through a panel using a threaded bulkhead body and locknuts. |
| PB Series | Male branch tee | Cylinder connection, manifold branching |
| PC Series | Male straight connector | General pneumatic lines, cylinders, valves |
| PCF Series | Female straight connector | Connection to valves, manifolds, actuators |
| PD Series | Male run tee | Branching from main supply line |
| PE Series | Union tee | Splitting main air line to two branches |
| PH Series | Male banjo elbow | Cylinder ports in compact spaces |
| PL Series | Male elbow | Corner mounting, small cabinets |
| PLF Series | Female elbow | Manifolds, valves, actuators |
| PLL Series | Extended male elbow | Deep valve blocks, recessed ports |
| PU Series | Union straight connector | Tube extension, repair of cut tubes |
| PV Series | Union elbow | Routing tube around corners |
| PX Series | Male Y connector | Parallel cylinder supply, dual actuators |
| PY Series | Union Y connector | Parallel lines for two actuators |
| PZA Series | Union cross | Complex manifolds, distribution blocks |
| SL Series | Speed controller | Speed control of cylinders and actuators |
Check the interface and operating conditions.
Choose a listed ordering group or enter the full model. Tube and thread ranges do not mean that every combination is available.
Push-in series — tube and connection options
Review the matching series above for its connection options and ordering information.
| Item | Value |
|---|---|
| Applicable tube | PU / PA |
| Medium | Air / Vacuum |
| Working pressure | 0 ~ 1.0 MPa |
| Temperature | 0 ~ 60°C, no freezing |
| Body / thread component | PBT / nickel-plated brass |
| Retention / seal | Stainless-steel claw / NBR |
Confirm required vacuum level and the exact model’s limits. Use clean, square-cut tubing and full insertion for a sound connection.
Check the complete connection.
Choose a listed ordering group or enter the full model. Tube and thread ranges do not mean that every combination is available.
Start with tube outside diameter
Select tube OD and material, then verify tolerance and insertion requirements. Tube ID is not the size reference for a push-in connection.
Choose the circuit geometry
Use port connectors at equipment, unions between tubes and bulkheads at cabinet walls. Leave access to the release collar for servicing.
Separate connection from control
DHVFF adds manual shut-off; DLSA and SL add flow control. For speed control, specify the flow direction and meter-in or meter-out requirement.
Check the complete circuit
Confirm working pressure, vacuum duty, temperature and medium for the fitting and tube together. Specify the port thread and sealing arrangement separately.
Selection questions.
Should I order by tube OD or ID?
Use tube outside diameter for push-in fittings. Also specify material and verify dimensional tolerance and surface condition.
Which fittings pass through a panel?
DPM is the bulkhead straight union for joining two tube lines through a panel. Confirm the mounting-hole diameter, panel thickness, tube size and locknut clearance.
Is a swivel elbow a rotary union?
Use the orientation feature to route tubing during installation. Confirm continuous rotation or repeated movement separately; a swivel fitting must not be assumed to be a rotary union.
Can I use the tube’s higher pressure rating for the assembly?
The allowable assembly pressure is limited by its lowest-rated tube, fitting, valve or other component at the actual temperature and medium conditions.