Push-in Fittings

Choose the connection shape, then match tube outside diameter and port thread. Compare straight, elbow and branch fittings alongside flow-control components.

Push-in Fittings
JEMWON fittings selection

Find the right connection.

Compare the form and tube interface first. Open a series to review its parameters and prepare the required configuration.

DHVFF Series — Manual hand valve

DHVFF Series

Manual hand valve

Tube / port options
Tube 4–12 mm / various
Sizes & ordering
DHVFF Series: Manual hand valve
Open original product image

DHVFF Series

Manual hand valve.

Connection form
Manual hand valve
Ordering prefix
HVFF
  • DHVFF is the series display name. Order codes use HVFF; retain the listed code when specifying the fitting.
  • Specify the required control function and flow direction together with tube size. Confirm the selected valve circuit and operating conditions.
Push-in series — tube and connection options
Series Tube / port options Connection form
DHVFF Series Tube 4–12 mm / various Manual shut-off valve

Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.

Listed order references
Listed code
HVFF-4
HVFF-6
HVFF-8
HVFF-10
HVFF-12

Prepare this configuration

Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.

Prepare a requirement brief

Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.

Copy your model and options into the requirement brief.

DLSA Series — In-line flow controller

DLSA Series

In-line flow controller

Tube / port options
Tube-to-tube; listed LSA sizes 4, 6, 8, 10, 12
Sizes & ordering
DLSA Series: In-line flow controller
Open original product image

DLSA Series

In-line flow controller.

Connection form
In-line flow controller
Ordering prefix
LSA
  • DLSA is the series display name. Order codes use LSA; retain the listed code when specifying the fitting.
  • Specify the required control function and flow direction together with tube size. Confirm the selected valve circuit and operating conditions.
Push-in series — tube and connection options
Series Tube / port options Connection form
DLSA Series Tube-to-tube; listed LSA sizes 4, 6, 8, 10, 12 In-line flow control

Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.

Listed order references
Listed code
LSA-4
LSA-6
LSA-8
LSA-10
LSA-12

Prepare this configuration

Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.

Prepare a requirement brief

Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.

Copy your model and options into the requirement brief.

DPG Series — Straight reducing union

DPG Series

Straight reducing union

Tube / port options
Unequal tube pairs; select the complete PG code
Sizes & ordering
DPG Series: Straight reducing union
Open original product image

DPG Series

Straight reducing union.

Connection form
Straight reducing union
Ordering prefix
PG
  • DPG is the series display name. Order codes use PG; retain the listed code when specifying the fitting.
Push-in series — tube and connection options
Series Tube / port options Connection form
DPG Series Unequal tube pairs; select the complete PG code Straight reducing union

Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.

Listed order references
Listed code
PG6-4
PG8-4
PG10-8
PG12-10
PG10-6
PG12-8
PG16-12

Prepare this configuration

Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.

Prepare a requirement brief

Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.

Copy your model and options into the requirement brief.

DPK Series — Five-port union

DPK Series

Five-port union

Tube / port options
Five tube ports; listed PK sizes 4, 6, 8, 10, 12
Sizes & ordering
DPK Series: Five-port union
Open original product image

DPK Series

Five-port union.

Connection form
Five-port union
Ordering prefix
PK
  • DPK is the series display name. Order codes use PK; retain the listed code when specifying the fitting.
Push-in series — tube and connection options
Series Tube / port options Connection form
DPK Series Five tube ports; listed PK sizes 4, 6, 8, 10, 12 Five-port union

Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.

Listed order references
Listed code
PK-4
PK-6
PK-8
PK-10
PK-12

Prepare this configuration

Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.

Prepare a requirement brief

Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.

Copy your model and options into the requirement brief.

DPM Series — Bulkhead straight union

DPM Series

Bulkhead straight union

Tube / port options
Tube-to-tube bulkhead; listed PM sizes 4, 6, 8, 10, 12
Sizes & ordering
DPM Series: Bulkhead straight union
Open original product image

DPM Series

Bulkhead straight union.

Connection form
Bulkhead straight union
Ordering prefix
PM
  • DPM is the series display name. Order codes use PM; retain the listed code when specifying the fitting.
Push-in series — tube and connection options
Series Tube / port options Connection form
DPM Series Tube-to-tube bulkhead; listed PM sizes 4, 6, 8, 10, 12 Bulkhead straight union

Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.

Listed order references
Listed code
PM-4
PM-6
PM-8
PM-10
PM-12

Prepare this configuration

Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.

Prepare a requirement brief

Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.

Copy your model and options into the requirement brief.

PB Series — Male branch tee

PB Series

Male branch tee

Tube / port options
Tube 4–12 mm; male thread M5–1/2"
Sizes & ordering
PB Series: Male branch tee
Open original product image

PB Series

Male branch tee.

Connection form
Male branch tee
Ordering prefix
PB
Push-in series — tube and connection options
Series Tube / port options Connection form
PB Series Tube 4–12 mm; male thread M5–1/2" Branch tee with male thread

Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.

Listed order references
Order-code group
PB4-M5/M6
PB4-01/02/03/04
PB6-M5/M6
PB6-01/02/03/04
PB8-01/02/03/04
PB10-01/02/03/04
PB12-01/02/03/04
PB14-02/03/04/06
PB16-02/03/04/06

Prepare this configuration

Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.

Prepare a requirement brief

Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.

Copy your model and options into the requirement brief.

PC Series — Male straight connector

PC Series

Male straight connector

Tube / port options
Tube 4–16 mm; male thread M5–1/2"
Sizes & ordering
PC Series: Male straight connector
Open original product image

PC Series

Male straight connector.

Connection form
Male straight connector
Ordering prefix
PC
Push-in series — tube and connection options
Series Tube / port options Connection form
PC Series Tube 4–16 mm; male thread M5–1/2" Straight push-in connector

Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.

Listed order references
Order-code group
PC4-M5/M6
PC4-01/02/03/04
PC6-M5/M6
PC6-01/02/03/04
PC8-01/02/03/04
PC10-01/02/03/04
PC12-01/02/03/04
PC14-02/03/04/06
PC16-02/03/04/06

Prepare this configuration

Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.

Prepare a requirement brief

Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.

Copy your model and options into the requirement brief.

PCF Series — Female straight connector

PCF Series

Female straight connector

Tube / port options
Tube 4–12 mm; female thread 1/8–1/2"
Sizes & ordering
PCF Series: Female straight connector
Open original product image

PCF Series

Female straight connector.

Connection form
Female straight connector
Ordering prefix
PCF
Push-in series — tube and connection options
Series Tube / port options Connection form
PCF Series Tube 4–12 mm; female thread 1/8–1/2" Straight with internal thread

Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.

Listed order references
Order-code group
PCF4-M5/M6
PCF4-01/02/03/04
PCF6-M5/M6
PCF6-01/02/03/04
PCF8-01/02/03/04
PCF10-01/02/03/04
PCF14-02/03/04
PCF16-02/03/04

Prepare this configuration

Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.

Prepare a requirement brief

Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.

Copy your model and options into the requirement brief.

PD Series — Male run tee

PD Series

Male run tee

Tube / port options
Tube 4–12 mm; male thread M5–1/2"
Sizes & ordering
PD Series: Male run tee
Open original product image

PD Series

Male run tee.

Connection form
Male run tee
Ordering prefix
PD
Push-in series — tube and connection options
Series Tube / port options Connection form
PD Series Tube 4–12 mm; male thread M5–1/2" In-line tee with male thread

Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.

Listed order references
Order-code group
PD4-M5/M6
PD4-01/02/03/04
PD6-M5/M6
PD6-01/02/03/04
PD8-01/02/03/04
PD10-01/02/03/04
PD12-01/02/03/04
PD14-02/03/04/06
PD16-02/03/04/06

Prepare this configuration

Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.

Prepare a requirement brief

Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.

Copy your model and options into the requirement brief.

PE Series — Union tee

PE Series

Union tee

Tube / port options
Tube 4–16 mm (all ports)
Sizes & ordering
PE Series: Union tee
Open original product image

PE Series

Union tee.

Connection form
Union tee
Ordering prefix
PE
Push-in series — tube and connection options
Series Tube / port options Connection form
PE Series Tube 4–16 mm (all ports) Equal union tee

Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.

Listed order references
Listed code
PE-4
PE-6
PE-8
PE-10
PE-12
PE-14
PE-16

Prepare this configuration

Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.

Prepare a requirement brief

Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.

Copy your model and options into the requirement brief.

PH Series — Male banjo elbow

PH Series

Male banjo elbow

Tube / port options
Tube 4–10 mm; male thread M5–1/2"
Sizes & ordering
PH Series: Male banjo elbow
Open original product image

PH Series

Male banjo elbow.

Connection form
Male banjo elbow
Ordering prefix
PH
Push-in series — tube and connection options
Series Tube / port options Connection form
PH Series Tube 4–10 mm; male thread M5–1/2" Banjo-type swivel elbow

Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.

Listed order references
Order-code group
PH4-M5/M6
PH4-01/02
PH6-M5/M6
PH6-01/02/03/04
PH8-01/02/03/04
PH10-01/02/03/04
PH12-01/02/03/04

Prepare this configuration

Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.

Prepare a requirement brief

Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.

Copy your model and options into the requirement brief.

PL Series — Male elbow

PL Series

Male elbow

Tube / port options
Tube 4–16 mm; male thread M5–1/2"
Sizes & ordering
PL Series: Male elbow
Open original product image

PL Series

Male elbow.

Connection form
Male elbow
Ordering prefix
PL
Push-in series — tube and connection options
Series Tube / port options Connection form
PL Series Tube 4–16 mm; male thread M5–1/2" 90° male elbow

Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.

Listed order references
Order-code group
PL4-M5/M6
PL4-01/02/03/04
PL6-M5/M6
PL6-01/02/03/04
PL8-01/02/03/04
PL10-01/02/03/04
PL12-01/02/03/04
PL14-02/03/04/06
PL16-02/03/04/06

Prepare this configuration

Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.

Prepare a requirement brief

Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.

Copy your model and options into the requirement brief.

PLF Series — Female elbow

PLF Series

Female elbow

Tube / port options
Tube 4–12 mm; female thread 1/8–1/2"
Sizes & ordering
PLF Series: Female elbow
Open original product image

PLF Series

Female elbow.

Connection form
Female elbow
Ordering prefix
PLF
Push-in series — tube and connection options
Series Tube / port options Connection form
PLF Series Tube 4–12 mm; female thread 1/8–1/2" 90° female elbow

Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.

Listed order references
Order-code group
PLF4-M5/M6
PLF4-01/02/03/04
PLF6-M5/M6
PLF6-01/02/03/04
PLF8-01/02/03/04
PLF10-01/02/03/04
PLF12-01/02/03/04
PLF14-02/03/04
PLF16-01/02/03/04

Prepare this configuration

Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.

Prepare a requirement brief

Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.

Copy your model and options into the requirement brief.

PLL Series — Extended male elbow

PLL Series

Extended male elbow

Tube / port options
Tube 4–12 mm; male thread M5–1/2"
Sizes & ordering
PLL Series: Extended male elbow
Open original product image

PLL Series

Extended male elbow.

Connection form
Extended male elbow
Ordering prefix
PLL
Push-in series — tube and connection options
Series Tube / port options Connection form
PLL Series Tube 4–12 mm; male thread M5–1/2" Extended 90° elbow

Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.

Listed order references
Order-code group
PLL4-M5/M6
PLL4-01/02/03/04
PLL6-M5/M6
PLL6-01/02/03/04
PLL8-01/02/03/04
PLL10-01/02/03/04
PLL12-01/02/03/04

Prepare this configuration

Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.

Prepare a requirement brief

Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.

Copy your model and options into the requirement brief.

PU Series — Union straight connector

PU Series

Union straight connector

Tube / port options
Tube 4–16 mm both sides
Sizes & ordering
PU Series: Union straight connector
Open original product image

PU Series

Union straight connector.

Connection form
Union straight connector
Ordering prefix
PU
Push-in series — tube and connection options
Series Tube / port options Connection form
PU Series Tube 4–16 mm both sides Equal union straight

Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.

Listed order references
Listed code
PU-4
PU-6
PU-8
PU-10
PU-12
PU-14
PU-16

Prepare this configuration

Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.

Prepare a requirement brief

Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.

Copy your model and options into the requirement brief.

PV Series — Union elbow

PV Series

Union elbow

Tube / port options
Tube 4–16 mm both ports
Sizes & ordering
PV Series: Union elbow
Open original product image

PV Series

Union elbow.

Connection form
Union elbow
Ordering prefix
PV
Push-in series — tube and connection options
Series Tube / port options Connection form
PV Series Tube 4–16 mm both ports Equal union elbow

Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.

Listed order references
Listed code
PV-4
PV-6
PV-8
PV-10
PV-12
PV-14
PV-16

Prepare this configuration

Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.

Prepare a requirement brief

Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.

Copy your model and options into the requirement brief.

PX Series — Male Y connector

PX Series

Male Y connector

Tube / port options
Tube 4–12 mm; male thread M5–1/2"
Sizes & ordering
PX Series: Male Y connector
Open original product image

PX Series

Male Y connector.

Connection form
Male Y connector
Ordering prefix
PX
Push-in series — tube and connection options
Series Tube / port options Connection form
PX Series Tube 4–12 mm; male thread M5–1/2" Y-type with male thread

Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.

Listed order references
Order-code group
PX4-M5/M6
PX4-01/02/03/04
PX6-M5/M6
PX6-01/02/03/04
PX8-01/02/03/04
PX10-01/02/03/04
PX12-01/02/03/04
PX14-02/03/04/06
PX16-02/03/04/06

Prepare this configuration

Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.

Prepare a requirement brief

Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.

Copy your model and options into the requirement brief.

PY Series — Union Y connector

PY Series

Union Y connector

Tube / port options
Tube 4–12 mm all ports
Sizes & ordering
PY Series: Union Y connector
Open original product image

PY Series

Union Y connector.

Connection form
Union Y connector
Ordering prefix
PY
Push-in series — tube and connection options
Series Tube / port options Connection form
PY Series Tube 4–12 mm all ports Equal union Y

Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.

Listed order references
Listed code
PY-4
PY-6
PY-8
PY-10
PY-12
PY-14
PY-16

Prepare this configuration

Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.

Prepare a requirement brief

Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.

Copy your model and options into the requirement brief.

PZA Series — Union cross

PZA Series

Union cross

Tube / port options
Tube 4–12 mm all directions
Sizes & ordering
PZA Series: Union cross
Open original product image

PZA Series

Union cross.

Connection form
Union cross
Ordering prefix
PZA
Push-in series — tube and connection options
Series Tube / port options Connection form
PZA Series Tube 4–12 mm all directions Equal cross union

Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.

Listed order references
Listed code
PZA-4
PZA-6
PZA-8
PZA-10
PZA-12

Prepare this configuration

Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.

Prepare a requirement brief

Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.

Copy your model and options into the requirement brief.

SL Series — Speed controller

SL Series

Speed controller

Tube / port options
Tube 4–12 mm; thread M5–1/2"
Sizes & ordering
SL Series: Speed controller
Open original product image

SL Series

Speed controller.

Connection form
Speed controller
Ordering prefix
SL
  • Specify the required control function and flow direction together with tube size. Confirm the selected valve circuit and operating conditions.
Push-in series — tube and connection options
Series Tube / port options Connection form
SL Series Tube 4–12 mm; thread M5–1/2" Meter-out / meter-in type

Series ranges are not a size/thread combination matrix. Select the full listed order code; confirm the thread standard and dimensions for the individual fitting.

Listed order references
Order-code group
SL4-M5/M6
SL4-01/02
SL6-M5/M6
SL6-01/02/03/04
SL8-01/02/03/04
SL10-01/02/03/04
SL12-01/02/03/04

Prepare this configuration

Use the complete code when requesting a fitting. Numeric thread suffixes need a confirmed thread standard; the code list is not a dimensional or pressure approval.

Prepare a requirement brief

Your selection carries into the brief tool. The tool creates text on your device; it does not send an online enquiry.

Copy your model and options into the requirement brief.

Compare the routing options.

One-touch fittings connect calibrated PU or PA tubing to pneumatic ports and to other tubes. Choose straight and elbow connectors, branches, panel feedthroughs or flow-control components, then match the tube outside diameter, port thread and connection function independently.

Compare the connection forms
Series Connection / function Circuit use
DHVFF Series Manual hand valve Line isolation, maintenance point, local on/off control
DLSA Series In-line flow controller Cylinder speed control, small pneumatic actuators
DPG Series Straight reducing union Join two different tube outside diameters in a straight line.
DPK Series Five-port union Connect five tube lines at one distribution junction.
DPM Series Bulkhead straight union Join two tube lines through a panel using a threaded bulkhead body and locknuts.
PB Series Male branch tee Cylinder connection, manifold branching
PC Series Male straight connector General pneumatic lines, cylinders, valves
PCF Series Female straight connector Connection to valves, manifolds, actuators
PD Series Male run tee Branching from main supply line
PE Series Union tee Splitting main air line to two branches
PH Series Male banjo elbow Cylinder ports in compact spaces
PL Series Male elbow Corner mounting, small cabinets
PLF Series Female elbow Manifolds, valves, actuators
PLL Series Extended male elbow Deep valve blocks, recessed ports
PU Series Union straight connector Tube extension, repair of cut tubes
PV Series Union elbow Routing tube around corners
PX Series Male Y connector Parallel cylinder supply, dual actuators
PY Series Union Y connector Parallel lines for two actuators
PZA Series Union cross Complex manifolds, distribution blocks
SL Series Speed controller Speed control of cylinders and actuators

Check the interface and operating conditions.

Choose a listed ordering group or enter the full model. Tube and thread ranges do not mean that every combination is available.

Push-in series — tube and connection options

Review the matching series above for its connection options and ordering information.

Return to the series

Push-in construction and operating conditions
Item Value
Applicable tube PU / PA
Medium Air / Vacuum
Working pressure 0 ~ 1.0 MPa
Temperature 0 ~ 60°C, no freezing
Body / thread component PBT / nickel-plated brass
Retention / seal Stainless-steel claw / NBR

Confirm required vacuum level and the exact model’s limits. Use clean, square-cut tubing and full insertion for a sound connection.

Check the complete connection.

Choose a listed ordering group or enter the full model. Tube and thread ranges do not mean that every combination is available.

Selection and replacement checklists

Start with tube outside diameter

Select tube OD and material, then verify tolerance and insertion requirements. Tube ID is not the size reference for a push-in connection.

Choose the circuit geometry

Use port connectors at equipment, unions between tubes and bulkheads at cabinet walls. Leave access to the release collar for servicing.

Separate connection from control

DHVFF adds manual shut-off; DLSA and SL add flow control. For speed control, specify the flow direction and meter-in or meter-out requirement.

Check the complete circuit

Confirm working pressure, vacuum duty, temperature and medium for the fitting and tube together. Specify the port thread and sealing arrangement separately.

Selection questions.

Should I order by tube OD or ID?

Use tube outside diameter for push-in fittings. Also specify material and verify dimensional tolerance and surface condition.

Which fittings pass through a panel?

DPM is the bulkhead straight union for joining two tube lines through a panel. Confirm the mounting-hole diameter, panel thickness, tube size and locknut clearance.

Is a swivel elbow a rotary union?

Use the orientation feature to route tubing during installation. Confirm continuous rotation or repeated movement separately; a swivel fitting must not be assumed to be a rotary union.

Can I use the tube’s higher pressure rating for the assembly?

The allowable assembly pressure is limited by its lowest-rated tube, fitting, valve or other component at the actual temperature and medium conditions.

Series information